Products  
K-ASSAY
 
 Search All Products
 
 
 Research Assay Kits
 - A B C D E F G H I J K
 - L M N O P Q R S T U
 - V W X Y Z  Other
 Animal / Preclinical Kits
 - A B C D E F G H I J K
 - L M N O P Q R S T U
 - V W X Y Z  Other
 
 Antibodies
 - A B C D E F G H I J K
 - L M N O P Q R S T U
 - V W X Y Z  Other
 Biochemicals
 - A B C D E F G H I J K
 - L M N O P Q R S T U
 - V W X Y Z  Other
 
 
 Research Interests 
 - Allergy
 - Anemia
 - Cancer
 - Cardiac
 
 Antibody Applications 
 - ELISA
 
KAMIYA Logo KAMIYA BIOMEDICAL COMPANY
K-ASSAY
   Home       About Kamiya       Catalog       Ordering       Contact Us   
In Business Since 1983 !
ISO    
13485:2003   
KAMIYA BIOMEDICAL COMPANY is an ISO 13485:2003 Certified Company. Most of our diagnostic products are CE Marked and readily available for use in clinical labs all over the world!

K-Assay
 
Clinical Diagnostics
Liquid Immunoassay Reagents
 





Transferrin
Cat. No.: KAI-023   or   KAI-101
Type.: Reagent
Method: Immunoturbidimetric
Format: Liquid
Linearity: 45 - 455 mg/dL
Sample: Serum


KIT COMPOSITION
Cat. No. KAI-023
R1:   3 X 20 mL buffer
R2:   2 X 10 mL antibody

Tests / Kit:   200 (Hitachi 717)
(Can Vary Based On Analyzer Model)
    
KAI-023
Click Image To Enlarge       




Cat. No. KAI-101
Note: Large size kit, available by special order.
R1:   3 X 60 mL buffer
R2:   1 X 60 mL antibody

Tests / Kit:   600 (Hitachi 717)
(Can Vary Based On Analyzer Model)

    
KAI-101
Click Image To Enlarge       


Click here for information about recommended calibrators and controls.


INTENDED USE
The K-ASSAY ®   Transferrin assay is intended for the quantitative determination of human transferrin in human serum by immunoturbidimetric assay.
FOR IN VITRO DIAGNOSTIC USE.

REAGENT PREPARATION
The reagents are ready to use and do not require reconstitution.

STORAGE AND HANDLING
All reagents should be stored refrigerated (2-8°C).  Return all reagents to 2-8°C promptly after use.  Unopened reagents can be used for one year from the date of manufacture, as indicated by the expiration date on the package and bottle labels.  Opened reagents can be used for one month if stored at 2-8°C.

PERFORMANCE
Precision
The precision for the K-ASSAY ®   Transferrin assay was determined using packaged reagents, pooled human serum, and a Hitachi 717 analyzer.

Precision - Within Run
Sample I Sample II Sample III
N = 20 N = 20 N = 20
Mean = 70.7 Mean = 300.75 Mean = 526.4
S.D. = 0.92 S.D. = 5.02 S.D. = 5.77
C.V. = 1.3% C.V. = 1.67% C.V. = 1.097%

Precision - Between Runs
Sample I Sample II
N = 8 N = 8
Mean = 175.38 Mean = 340.9
S.D. = 1.6 S.D. = 1.46
C.V. = 0.91% C.V. = 0.4%

Accuracy / Correlation
A comparison of the K-ASSAY ®   Transferrin assay to an Incstar Transferrin Test Kit was performed using a Hitachi 717.  The test results provided the following data:

y = 1.064x - 50.124
r = 0.982
n = 60
x = Incstar Transferrin Test Kit
y = K-ASSAY ®   Transferrin

x min = 148 y min = 110
  max = 440   max = 426
  mean = 246   mean = 212

Assay Range
45 - 455 mg/dL

INTERFERENCE
Ascorbic Acid :     No interference up to 50 mg/dL
Bilirubin F and C :     No interference up to 20 mg/dL
Hemoglobin :     No interference up to 500 mg/dL
Lipemia :     No interference up to 5%


12779 Gateway Drive, Seattle, WA 98168, USA  •  Tel: (206) 575-8068  •  Fax: (206) 575-8094  •  E-mail: info@k-assay.com